DISASSEMBLY OF AIRBRUSH
In each step of the disassembly,
refer to the diagram. Remove each part by horning or pulling in the direction
indicated by the arrow.
STEP 1: Pull air hose off the hose
connector
STEP 2: Remove (7) handle by turning
counter clockwise
STEP 3: Loosen (8) needle chuck
nut.
STEP 4: Pull needle out. Be careful
not to damage the point
STEP 5: Unscrew (11) spring guide
STEP 6: Remove (12) needle spring
and (10) needle chucking guide respectively.
STEP 7: Remove (5) main lever by
pulling then twisting and (6) auxiliary lever by twisting then pulling.
STEP 8: Remove (1) crown needle
cap and (2) nozzle cap respectively.
STEP9: Using the small flat wrench
received with the airbrush, remove (3) nozzle. Note: the nozzle has two
flat spots. Place the slot of the over these slots and turn counter clockwise.
CLEANING AND LUBRICATION Using KOPYKAKE Airbrush Cleaner submerge all pans' except the needle, in a glass or metal pan for a few minutes then scrub with a small paint brush until all color has been removed. Clean especially the color cup (4) THE AIRBRUSH COLORING GOES IN THIS CUP. Make sure you have a good liquid flow out of where the nozzle connects. Use a Q-tip to scrub the walls and to reach into the color cup. Rinse the parts with hot water and dry thoroughly with a lint-free cloth. Clean the needle with airbrush cleaner and check the point to make sure there is no damage. Look at the point of the needle for a bend or hook. Using a white piece of paper and placing the needle on it and rolling it will make it easier to see if damage exists and needs to be replaced.
ASSEMBLY
STEP 1: Using the nozzle wrench,
screw in then tighten the nozzle (3). Caution: do not apply excessive force
when tightening the nozzle.
STEP 2: Screw on the nozzle cap
(2) and hand tighten.
STEP 3: Screw on crown cap (1)
STEP 4: Hold the airbrush as show
in the diagram to complete
STEPS 4 and 5. Take auxiliary lever
(6) and hold as shown in Diagram C. Insert inside opening, twist so that
the hump is towards the back and let it rest against the back of the opening.
STEP 5: Before you perform
STEP 5, inspect main lever (5),
Notice there is a thinner rounded section on the flat part under the round
head. This side goes towards the back of the opening. Refer to Diagram
B. Insert main lever (5) into opening and guide the two pins into the two
channels located on the walls inside the opening. Move head back against
the auxiliary lever (6) and hold there. Hold these parts (5) and (6) secure
with your finger and go to
STEP 6: Insert needle chucking guide
(10) channel down into back of the airbrush. Slide needle spring (12) over
needle chucking guide (10). Insert spring guide (11) over spring (12) screw
in and tighten. This spring mechanism will push the main lever and auxiliary
lever forward.
STEP 7: Insert the needle through
needle chucking guide (10) and slowly push all the way forward. Screw on
the chucking nut and tighten securely.
STEP 8: Cover the back of the airbrush